New generation X-ray imaging system
+8618024080604 | marketing@haozhigp.com

The world's leading new generation of carbon nanotube electron source technology, the field emission current density reaches 80A/cm2, and the total emission reaches 800mA.

Carbon nanotube X-ray tube breaks through the technical bottleneck of traditional X-ray tube, and solves the difficult technical problems of traditional CT system
such as long-term warm-up, inability to turn on and off at high speed, high power consumption and low imaging resolution;

The ultra-high-speed pulse exposure of the carbon nanotube CT tube can effectively eliminate the motion blur and
artifacts of the traditional X-ray CT equipment, and can greatly reduce the useless radiation dose.

Ultra-low power consumption, the external photon efficiency of the carbon nanotube cold cathode X-ray tube developed is more than 3 times that of the traditional hot cathode X-ray tube.

The material technologies used in the front panel of the company's Shanghai Haobo Imaging X-ray flat panel detector are amorphous silicon (a-Si), oxide (IGZO) and CMOS.

These three types of flat panel detectors have the characteristics of high image quality, large dynamic range, and wide terminal application range.

The iterative CT reconstruction algorithm based on the compressed sensing theory greatly improves the scanning efficiency and saves the scanning time and the exposure time of the ray source, and supports the low-angle CT reconstruction.

The industry's ultra-high-speed ultra-high-speed scanning and CT reconstruction of a specific area, for the first time to complete the scanning and CT reconstruction process within 2s;

High-definition image processing filter function, rich measurement and analysis tools, simple semi-automatic programming tools, AI recognition algorithm can be customized;

Scanning and CT reconstruction are carried out at the same time, and CT three-dimensional data can be output immediately after the scan. It includes a variety of scanning protocols and supports scanning protocol customization;

It can be connected to the industry's top image post-processing and analysis software.

There are 2 doctors and 15 masters

R & D personnel with bachelor degree or above 100%

R & D personnel account for 76%

The corresponding formula of Guangdong Province is less than 2 hours, and the arrival time at the site is less than 8 hours;

The corresponding time in Chinese mainland is less than 2 hours and the time of arriving at the scene is less than 48 hours.

The overseas response time is less than 8 hours, and the arrival time at the site shall be as agreed in the contract;